CFI-I SAMPLE QUESTIONS, UPDATED CFI-I TESTKINGS

CFI-I Sample Questions, Updated CFI-I Testkings

CFI-I Sample Questions, Updated CFI-I Testkings

Blog Article

Tags: CFI-I Sample Questions, Updated CFI-I Testkings, Reliable CFI-I Exam Tutorial, New CFI-I Exam Vce, Test CFI-I Dumps

Our customer service is available all day, and your problems can be solved efficiently at any time. Last but not least, we can guarantee the security of the purchase process of CFI-I Test Questions and the absolute confidentiality of customer information. You do not have to worry about these issues, because we know that this is a basic condition for us to establish a good business model. If you have any questions, you can always contact us online or email us. We will reply as soon as possible.

We strongly recommend using our Certified Fire Inspector I (CFI-1) (CFI-I) exam dumps to prepare for the NFPA CFI-I certification. It is the best way to ensure success. With our Certified Fire Inspector I (CFI-1) (CFI-I) practice questions, you can get the most out of your studying and maximize your chances of passing your Certified Fire Inspector I (CFI-1) (CFI-I) exam.

>> CFI-I Sample Questions <<

Simplified Document Sharing and Accessibility With NFPA CFI-I PDF (Questions)

“Quality First, Credibility First, and Service First” is our company’s purpose, we deeply hope our CFI-I Study Materials can bring benefits and profits for our customers. So we have been persisting in updating in order to help customers, who are willing to buy our test torrent, make good use of time and accumulate the knowledge. We will guarantee that you will have the opportunity to use the updating system for free.

NFPA CFI-I Exam Syllabus Topics:

TopicDetails
Topic 1
  • Fire Protection Systems & Equipment: This section evaluates the skills of Fire Safety Technicians and focuses on determining the operational readiness of fire suppression systems, alarm systems, and portable fire extinguishers.
Topic 2
  • Storage, Handling, & Use of Hazardous Substances and Materials: This module measures the skills of Fire Inspectors and includes recognizing hazardous conditions in equipment, processes, and operations.
Topic 3
  • Administration: This section of the exam measures the skills of Fire Inspectors and covers the preparation of inspection reports, identifying the need for permits, and recognizing when plan reviews are required. It also involves investigating complaints, identifying applicable codes, and participating in legal proceedings. One key skill measured is communicating findings clearly in written reports.
Topic 4
  • Occupancy Types: This section tests the abilities of exam-takers to assess fire and life safety systems for different occupancy types, including assembly, educational, and healthcare facilities.

NFPA Certified Fire Inspector I (CFI-1) Sample Questions (Q78-Q83):

NEW QUESTION # 78
Portable LP gas cooking equipment is allowed to be used in a restaurant when it complies with which of the following?

  • A. NFPA 54
  • B. NFPA 58
  • C. NFPA 52
  • D. NFPA 96

Answer: B

Explanation:
Comprehensive and Detailed Step-by-Step Explanation:
LP Gas Equipment Regulations:
NFPA 58 (Liquefied Petroleum Gas Code) provides standards for the use, storage, and operation of portable LP gas equipment, including safety requirements for restaurants and other commercial applications.
Why NFPA 58 Applies:
Portable LP gas cooking equipment poses unique hazards due to the flammability of the gas. NFPA 58 ensures proper installation and operation to minimize risks.
Other Options Explained:
Option A (NFPA 52): Applies to natural gas vehicles, not cooking equipment.
Option B (NFPA 54): Covers natural gas fuel systems, not LP gas.
Option D (NFPA 96): Focuses on ventilation and grease removal in cooking systems, not LP gas-specific requirements.
Summary:
Portable LP gas cooking equipment in a restaurant must comply with NFPA 58 for safe operation.


NEW QUESTION # 79
The NFPA Standard for the installation of stationary pumps for fire protection is:

  • A. NFPA 25
  • B. NFPA 24
  • C. NFPA 13
  • D. NFPA 20

Answer: D

Explanation:
The standard for the installation of stationary fire pumps is specified in NFPA 20, Standard for the Installation of Stationary Pumps for Fire Protection.
NFPA 13 (A): Focuses on sprinkler system design and installation.
NFPA 20 (B): Covers the requirements for stationary pumps used in fire protection systems, including installation, performance, and acceptance testing.
NFPA 24 (C): Regulates private fire service mains and their appurtenances.
NFPA 25 (D): Outlines inspection, testing, and maintenance for water-based fire protection systems.
Reference:
NFPA 20, Chapter 4: Requirements for stationary fire pumps.


NEW QUESTION # 80
A fire inspector is inspecting a fast-food restaurant that has an indoor playground structure exceeding 10 ft (3.1 m) in height and 160 ft³ (14.9 m²) in are a. Which of the following statements is true regarding combustible materials used in the playground structure's construction?

  • A. Class II interior floor finish is permitted
  • B. Combustible materials are not permitted
  • C. Wood components may be treated or non-treated
  • D. Foam plastics with a heat-release rate less than 100 kW are permitted

Answer: D

Explanation:
Indoor playground structures are subject to material restrictions to prevent excessive fire risk. According to NFPA 101, Life Safety Code, Section 12.4.8.6, and related codes:
Combustible materials (A): Not all combustibles are prohibited; specific limits and fire-retardant materials are allowed.
Class II floor finish (B): This applies to interior finishes but does not directly address playground structure construction.
Wood components (C): Untreated wood is not acceptable in this case; treated materials might be allowed but are not sufficient alone.
Foam plastics (D): Foam plastics are permitted if the heat-release rate is less than 100 kW when tested per NFPA 289. This ensures they do not contribute significantly to fire growth.
Reference:
NFPA 101, Section 12.4.8.6: Material requirements for indoor playground structures.
NFPA 289: Standard test method for fire testing of foam plastics.


NEW QUESTION # 81
How often must a hose valve on a hose station attached to a sprinkler system and Class II standpipe system be tested?

  • A. Every three years
  • B. Every two years
  • C. Every year
  • D. Every four years

Answer: C

Explanation:
Comprehensive and Detailed Step-by-Step Explanation:
Testing Requirements for Hose Valves:
Hose valves in Class II standpipe systems and sprinkler systems are critical components for fire protection.
NFPA 25 (Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems), Section 6.3.1 requires hose valves to be tested annually to ensure proper operation and water flow.
Why Annual Testing is Required:
Regular testing ensures the valves function correctly in case of an emergency.
Annual testing helps identify potential issues such as leaks, corrosion, or improper operation.
Other Options Explained:
Option B (Every two years), Option C (Every three years), Option D (Every four years):
These frequencies do not meet the minimum requirements stated in NFPA 25 for hose valves on standpipe and sprinkler systems.
Summary:
Hose valves on a Class II standpipe system and sprinkler systems must be tested annually per NFPA 25 to ensure operational readiness.


NEW QUESTION # 82
What is the maximum travel distance from point A (fire extinguisher) to point B for the occupancy hazard associated with the floorplan?

  • A. 75 ft (22.9 m)
  • B. 50 ft (15.3 m)
  • C. 100 ft (30.5 m)
  • D. 25 ft (7.6 m)

Answer: A

Explanation:
Comprehensive and Detailed Step-by-Step Explanation:
Fire Extinguisher Travel Distance:
According to NFPA 10 (Standard for Portable Fire Extinguishers), Section 6.2.1, the maximum travel distance to a fire extinguisher depends on the hazard classification:
Light Hazard: 75 ft (22.9 m).
Ordinary Hazard: 75 ft (22.9 m).
Extra Hazard: 50 ft (15.3 m).
Why 75 Feet is Commonly Used:
For most general occupancies with light or ordinary hazards, the maximum allowable travel distance is 75 feet.
Other Options Explained:
Option A (25 ft): Used for Class K extinguishers in kitchens or special hazards.
Option B (50 ft): For higher hazard areas (extra hazard).
Option D (100 ft): Exceeds the NFPA 10 limits.
Summary:
The maximum travel distance to a fire extinguisher in light or ordinary hazard occupancies is 75 feet (22.9 m).


NEW QUESTION # 83
......

We will offer the preparation for the CFI-I training materials, we will also provide you the guide in the process of using. The materials of the exam dumps offer you enough practice for the CFI-I as well as the knowledge points of the CFI-I exam, the exam will bacome easier. If you are interested in the CFI-I training materials, free demo is offered, you can have a try. And the downloding link will send to you within ten minutes, so you can start your preparation as quickly as possible. In fact, the outcome of the CFI-I Exam most depends on the preparation for the CFI-I training materials. With the training materials, you can make it.

Updated CFI-I Testkings: https://www.vceengine.com/CFI-I-vce-test-engine.html